04407A1 |
Hydrogen Purity Analyser Base |
|
includes report software, SS liners, packaging |
|
|
Trace (>10 ppm), Pack 1 |
N2 Impurity - Enter range & LDL |
|
0-10ppm ≤N2 range ≤ 0-200ppm LDL is 1.5% full scale |
|
(with O2 trap in aux oven) |
|
|
Trace (>10 ppm), Pack 2 |
Same as Pack 1 + |
|
CO2 Impurity - Enter range & LDL |
|
0-10ppm ≤CO2 range ≤ 0-200ppm LDL is 1.5% full scale |
|
CH4 Impurity - Enter range & LDL |
|
0-10ppm ≤CH4 range ≤ 0-200ppm LDL is 1.5% full scale |
|
|
Trace (>10 ppm), Pack 3 |
CO Impurity - Enter range & LDL |
|
0-10ppm ≤CO range ≤ 0-200ppm LDL is 1.5% full scale |
|
CO2 Impurity - Enter range & LDL |
|
0-10ppm ≤CO2 range ≤ 0-200ppm LDL is 1.5% full scale |
|
CH4 Impurity - Enter range & LDL |
|
0-10ppm ≤CH4 range ≤ 0-200ppm LDL is 1.5% full scale |
|
|
Trace (>10 ppm), Pack 4 |
Same as Pack 2 + |
|
CO Impurity - Enter range & LDL |
|
0-10ppm ≤CO range ≤ 0-200ppm LDL is 1.5% full scale |
|
|
Trace (>10 ppm), Pack 5 |
Same as Pack 4 + |
|
Ar Impurity - Enter range & LDL |
|
0-10ppm ≤Ar range ≤ 0-200ppm LDL is 1.5% full scale |
|
|
Trace Exact (<10 ppm), Pack 1 |
N2 Impurity - Enter range & LDL (with O2 trap in aux oven) |
|
0-1ppm ≤N2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Min Range 0-1 ppm |
CO2 Impurity - Enter range & LDL |
|
0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
CH4 Impurity - Enter range & LDL |
|
0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
Trace Exact (<10 ppm), Pack 2 |
CO Impurity - Enter range & LDL |
|
0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Min Range 0-1 ppm |
CO2 Impurity - Enter range & LDL |
|
0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
CH4 Impurity - Enter range & LDL |
|
0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
Trace Exact (<10 ppm), Pack 2 |
Same as Pack 1 + |
|
CO Impurity - Enter range & LDL |
Min Range 0-1 ppm |
0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
Carrier Gas |
Argon |
|
Helium (if Argon impurity) |
|
|
Power |
115 VAC, 50-60 Hz |
|
220 VAC, 50-60 Hz |
|
|
Gas Connectors (to match accessories fittings) |
1/8" Swagelok |
|
1/8" VCR (if 0-1 ppm range) |
|
|
Serial port |
Not Required |
|
RS-232 |
|
|
Remote Support |
VNC |
|
Net Support |
|
|
Dual Inlets (sample + span, with switching) |
Not Required |
|
Required |
|
|
Calibration using background gas |
Not required |
|
Required |
|
|
|
|
|
|
04408A1 |
Carbon Dioxide Purity Analyser Base |
|
includes report software, SS liners, packaging |
|
|
Trace (>10 ppm), Pack 1 |
O2 Impurity - Enter range & LDL |
|
0-10ppm ≤O2 range ≤ 0-100ppm LDL is 1.5% full scale |
|
H2 Impurity - Enter range & LDL |
|
0-10ppm ≤H2 range ≤ 0-100ppm LDL is 1.5% full scale |
|
N2 Impurity - Enter range & LDL |
|
0-10ppm ≤N2 range ≤ 0-100ppm LDL is 1.5% full scale |
|
CH4 Impurity - Enter range & LDL |
|
0-10ppm ≤CH4 range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
Trace (>10 ppm), Pack 2 |
Same as Pack 1 + |
|
CO Impurity - Enter range & LDL |
|
0-10ppm ≤CO range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
Trace (>10 ppm), Pack 3 |
Same as Pack 2 + |
|
Ar Impurity - Enter range & LDL |
|
0-10ppm ≤Ar range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
Carrier Gas |
Argon |
|
Helium (if Argon impurity) |
|
|
Power |
115 VAC, 50-60 Hz |
|
220 VAC, 50-60 Hz |
|
|
|
|
Gas Connectors (to match accessories fittings) |
1/8" Swagelok |
|
1/8" VCR (if 0-1 ppm range) |
|
|
Serial port |
Not Required |
|
RS-232 |
|
|
Remote Support |
VNC |
|
Net Support |
|
|
Dual Inlets (sample + span, with switching) |
Not Required |
|
Required |
|
|
Calibration using background gas |
Not required |
|
Required |
|
|
|
|
|
|
|
|
SERVOFLEX 5200 MULTI PURPOSE ANALYSER |
|
|
|
05230A1 |
5200 Multi Purpose |
|
|
SUPPLY POWER |
UK Mains |
|
European Mains |
|
US Mains |
|
Japanese Mains (no plug fitted) |
|
Rechargeable Lithium ion battery (UK) |
|
Rechargeable Lithium ion battery (US) |
|
Rechargeable Lithium ion battery (Euro) |
|
Rechargeable Lithium ion battery (Japan) |
|
|
MEASUREMENT 1 |
Oxygen, standard accuracy (1116) |
|
Oxygen, industrial version (3601, 1 dec place) |
|
Oxygen, high accuracy (3601, 2 dec place) |
|
0-10% Carbon Dioxide |
|
0-25% Carbon Dioxide |
|
0-50% Carbon Dioxide |
|
0-100% Carbon Dioxide |
|
|
MEASUREMENT 2 |
0-10% Carbon Dioxide |
|
0-25% Carbon Dioxide |
|
0-50% Carbon Dioxide |
|
0-100% Carbon Dioxide |
|
|
SAMPLING |
Automatic Flow Control Device |
|
Internal Pump |
|
|
mA OUTPUTS |
mA outputs, one transducer fitted |
|
mA outputs, two transducers fitted |
|
|
CONNECTORS |
Quickconnect 1/4" barb fitting |
|
Barb as above plus adaptor to 1/8" NPT |
|
|
EXHAUST / VENT OUTLETQ |
Rear Panel |
|
Front Panel |
|
|
VEHICLE ADAPTOR |
12/24V Vehicle Power Adaptor |
|
|
PRINTER* |
Thermal Printer Kit (Universal) |
|
|
SIDE PANEL ACCESSORIES |
Sample Conditioning Panel (not for O2 std transducer) |
Choose only one |
Flow Meter + Valve (not for AFCD version) |
|
Flow Meter (analyser with AFCD) |
|
|
PROBE HOLDER |
Supplied (for SCP only) |
|
Supplied including Filter (not for SCP) |
|
|
SAMPLE PROBE |
Not Supplied |
|
25cm, SS, Tip, <180C |
|
1m SS |
|
|
TRANSPORT CASE |
None |
|
Protective plastic transport case, std pre-cut foam |
|
|
USER MANUAL |
English |
|
French |
|
German |
|
Italian |
|
|
ACCESSORIES |
|
202517 |
Additional barbed Quickconnect fitting |
|
(1 supplied as standard. Some users may wish |
|
to purchase additional fittings for zero and span |
|
gas to speed connections during calibration) |
|
|
5200991 |
Additional Quickconnect adaptor to 1/8" NPT |
|
|
203022 |
Additional rolls of printer paper (pack of 5) |
|
|
570982 |
Replacement filters (pack of 5) |
|
NOTE: 3 filters supplied with analyser |
|
|
2323-7029 |
Replacement Viton O-ring for AFCD |
|
|
5200992 |
Carry Case with foam inserts |
|
|
Note: If printer ordered as loose item after initial purchase price is higher |
209961 |
Thermal Printer Kit (Universal)*** |
|
|
*This price only when purchased with analyser. Includes 1 roll of paper. |
|
|
***The instrument will only print properly to the printer supplied by Servomex. |
|
|
SERVOFLEX 5200 FOOD PACK ANALYSER |
|
|
|