Features and Benefits

  • Transmits up to 2 km over optical fiber
  • Converts CAN signals to fiber and fiber to CAN signals
  • Baudrate up to 1 Mbps
  • Dual power inputs for redundancy
  • DIP switch for 120 ohm terminal resistance
  • DIP switch for fiber test mode
  • LEDs for Fiber TX, Fiber RX, Power 1, Power 2
  • Wide temperature model available for -40 to 85°C environments
  • Fully compatible with the ISO 11898 standard
CAN Communication
CAN Interface ISO 11898-2, Terminals (CAN_H, CAN_L,CAN_GND)
Protocols CAN 2.0A and 2.0B (ISO 11898-2)
Connector Type 3-pin removable screw terminal x1
Termination Resistor Dip switch selector for 120 Ω terminal resistor
Transfer Rate Up to 1 Mbps
System Delay 150 ns
Isolation Protection 2 kV
Transmission Distance Max 2 km (depends on the data rate and the protocol used) 
Note: The transmission distance is limited by the signal rate, as indicated in the ISO 11898-2 standard.
LED Indicators PWR1, PWR2, Fiber TX, Fiber RX
• Fiber Communication
Connector Type ST (multi-mode) fiber ports
Fiber Cable Requirements
• Physical Characteristics
Housing Metal
Dimensions 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
Weight 178 g (0.39 lb)
• Environmental Limits
Operating Temperature Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
• Power Requirements
Input Voltage 12 to 48 VDC dual power for redundant power
Input Current ICF-1170I: 221 mA @ 12 VDC
Alarm Contact: 1 relay output with current-carrying capacity of 1 A @ 24 VDC
Voltage Reversal Protection Protects against V+/V- reversal
Overcurrent Protection 1.1 A (protects against two signals shorted together)
• Standards and Certifications
Safety UL 508
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS EN 61000-4-2 (ESD): Contact: 8 kV; Air: 15 kV
EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m
EN 61000-4-4 (EFT): Power: 4 kV; Signal: 2 kV
EN 61000-4-5 (Surge): Power: 2 kV; Signal: 1 kV
EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m
EN 61000-4-8 (PFMF)
Green Product RoHS, CRoHS, WEEE
Freefall IEC 60068-2-32
• MTBF (mean time between failures)
Time 792,085 hrs
Standard Telcordia (Bellcore), GB