VA 500 - Flow sensor
Model: VA 500
Xuất sứ: Germany
Nhà cung cấp: Anh Nghi Sơn – ANS VietNam
Hãng sản xuất: CS-Instrument
VA 500 - Flow sensor Cs Instrument VietNam, Flow sensor VA 500 Cs Instrument VietNam, 0695 5001 Cs Instrument, Cs Instrument Đại Lý Việt Nam.
Cs Instruments Vietnam. Nhà cung cấp Anh Nghi Sơn - ANS Viet Nam.
Cung cấp tất cả máy móc, thiết bị của Cs Instruments Vietnam.
Flow sensor for compressed air and gas - VA 500
Contrary to the previously used bridge circuit the newly developed evaluation electronics of our flow sensor records all measured values digitally. This leads to a better accuracy also in case of large measuring spans of 1:1000.
Special features of flow sensor VA 500:
- RS 485 interface, Modbus-RTU as a standard
- Option integrated display for m³/h and m³
- Usable from 1/2“ to 12“ (DN 300)
- Easy installation under pressure
- 4...20 mA analogue output for m³/h resp. m³/min
- Pulse output for m³
- Inner diameter adjustable via keypad
- Consumption counter resettable
- Adjustable values at the display of the flow sensor: Reference conditions, °C and mbar, 4...20 mA scaling, pulse weight
TECHNICAL DATA VA 500
Parameters: m³/h, l/min (1000 mbar, 20 °C) in case of compressed air resp. Nm³/h, Nl/min (1013 mbar, 0 °C) in case of gases
Units adjustable via keys at display: m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h
Adjustable via keypad: Diameter for volume flow calculation, counter resettable
Sensor: Thermal mass flow sensor
Measuring medium Air, gases
Gas types are adjustable over CS service software or CS data logger: Air, nitrogen, argon, helium, CO2, oxygen, vacuum
Accuracy: (m.v.: of meas. value) (f.s.: of full scale) ± 1.5 % of m.v. ± 0.3 % of f.s. on request ± 1.0 % of m.v. ± 0.3 % of f.s.
Operating temperature: -30...110 °C probe tube -30...80 °C housing
Operating pressure: -1...50 bar
Digital output: RS 485 interface (Modbus-RTU), Optional: Ethernet-Interface PoE), M-Bus
Analog output: 4...20 mA for m³/h e. g. l/min;
Pulse output: 1 Pulse per m³ or per liter galvanically isolated. Pulse value can be set on the display. Alternatively, the pulse output can be used as an alarm relay
Supply: 18...36 VDC, 5 W
Burden: < 500 Ω
Housing: Polycarbonate (IP 65)
Probe tube: Stainless steel, 1.4301 Mounting length 220 mm, Ø 10 mm
Mounting thread: G 1/2“
Ø Casing: 65 mm
Mounting position: any
Measuring range: | |||
Max-version (185m/s) | Z695 5003 | ||
High-Speed-Version (224 m/s) | Z695 5002 | ||
Option display: | |||
with integrated display | Z695 5000 | ||
without display | |||
Option signal output / bus connection: | |||
Standard | |||
Ethernet-Interface for VA500/VA520, FA500 | Z695 5006 | ||
Ethernet-Interface PoE for VA500/VA520, FA500 | Z695 5007 | ||
M-Bus (pulse output not available) | Z695 5004 | ||
Mounting length / shaft length: | |||
220 mm | ZSL0220 | ||
120 mm | ZSL0120 | ||
160 mm | ZSL0160 | ||
300 mm | ZSL0300 | ||
400 mm | ZSL0400 | ||
500 mm | ZSL0500 | ||
600 mm | ZSL0600 | ||
700 mm | ZSL0700 | ||
Surface condition: | |||
Special cleaning - oil and grease free (e.g. for oxygen) | 0699 4005 | ||
LABS free and silicone free version incl.cleaning oil and grease free | 0699 4007 |
Special measuring range: | |||
Special measuring range freely selectable | Z695 4006 | ||
Accuracy class: | |||
± 1 % of measured value (precision) | Z695 5005 | ||
Further accessories: | |||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | ||
Welding neck, L = 35 mm male screw, R1/2",stainless steel 1.4301 | 3300 0006 | ||
Welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | ||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | ||
Connection cables: | |||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | ||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | ||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | ||
Ethernet-connection cable length 5 m, M 12 plug x-coded (8 poles) to RJ45 | 0553 2503 | ||
Ethernet-connection cable length 10 m, M 12 plug x-coded (8 poles) to RJ45 | 0553 2504 | ||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 5 m |
0553 0106 | ||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 10 m |
0553 0107 | ||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | ||
Mains units: | |||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | ||
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520 | 0554 0109 | ||
External display, chart recorder DS 400 | 0500 4000 | ||
Calibration and adjustment - Hiệu chuẩn | |||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | ||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | ||
Real gas calibration | 3200 0015 |
Liên hệ: Nguyễn Chí Hải
Sdt: 0398991575
Gmail: hai@ansgroup.asia