http://thietbitudong.ansvietnam.com/ |
|
04416A1 |
SERVOPRO NanoChrome Ar Background |
|
includes report software, packaging |
Impurities options |
|
N2 Range 0-250ppb LDL 0.3ppb |
INJ with 1 valve |
H2 Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2 valves |
CO Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CO2 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CO2/CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb |
BF/HC/SEL with 3 valves |
|
|
Chassis options (Refer to SAP) |
|
Master Chassis |
Max. 2 channels with 4 valves |
PC+ Slave chassis |
2 BF/HC channels |
Master +Slave1 Chassis |
Max. 4 channels with 8 valves |
|
|
Carrier Gas |
Helium |
|
Argon only for N2 measurement |
|
|
Power |
115 VAC, 50-60 Hz |
|
220 VAC, 50-60 Hz |
|
|
Gas Connectors (to match accessories fittings) |
1/8" VCR |
|
|
Serial port |
RS-232 |
|
|
|
|
Remote Support |
VNC |
|
Net Support |
|
|
Internal Dilution System |
Not Required( > 1ppm) |
|
Required ( One per Chassis) |
|
|
|
|
|
|
04416A1 |
SERVOPRO NanoChrome N2 Background |
|
includes report software, packaging |
Impurities options |
|
Ar Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2 valves |
H2 Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2 valves |
CO Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CO2 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CO2/CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb |
BF/HC/SEL with 3 valves |
|
|
Chassis options |
|
Master Chassis |
Max. 2 channels with 4 valves |
PC+ Slave chassis |
2 BF/HC channels |
Master +Slave1 Chassis |
Max. 4 channels with 8 valves |
Master +Slave 1 +Slave 2 Chassis |
Max. 6 channels with 12 valves |
|
|
Carrier Gas |
Helium |
|
|
|
|
Power |
115 VAC, 50-60 Hz |
|
220 VAC, 50-60 Hz |
|
|
Gas Connectors (to match accessories fittings) |
1/8" VCR |
|
|
Serial port |
RS-232 |
|
|
|
|
Remote Support |
VNC |
|
Net Support |
|
|
Internal Dilution System |
Not Required( > 1ppm) |
|
Required ( One per Chassis) |
|
|
|
|
|
|
|
|
SERVOPRO Plasma Gas Analyser (K2001) |
|
|
|
02001A1 |
Trace Gas Analyser |
|
|
|
includes 4-20ma, digital dry contacts (range ID), manual/CDROM, packaging) |
|
|
Power |
115 VAC, 50-60 Hz |
|
220 VAC, 50-60 Hz |
|
|
|
|
Background |
Argon |
|
Helium |
|
Argon and Helium |
|
|
|
|
Auto calibration |
Not required |
|
Required |
|
|
|
|
3 Range ID |
0-1, 0-10, 0-100 (ppm) |
|
0-10, 0-50, 0-100 (ppm) |
|
|
|
|
Serial port |
Not Required |
|
RS-232 |
|
|
|
|
|
|
|
|
|
|
SERVOPRO Chroma Gas Analyser (K4000) |
|
|
|
|
|
04401A1 |
Crude Ar Analyser (N2 in mix 10%Ar + 90%O2) Base |
|
includes report software, 2 SS coils tubing, packaging |
|
|
Trace (>10 ppm), Pack 1 |
N2 Impurity - Enter range & LDL |
|
0-10ppm ≤N2 range ≤ 0-500ppm LDL is 1.5% full scale |
Carrier Gas |
Argon |
|
|
Power |
115 VAC, 50-60 Hz |
|
220 VAC, 50-60 Hz |
|
|
Gas Connectors |
1/8" Swagelok |
(to match accessories fittings) |
|
|
|
Serial port |
Not Required |
|
RS-232 |
|
|
Remote Support |
VNC |
|
Net Support |
|
|
Dual Inlets (sample + span, with switching) |
Not Required |
|
Required |
|
|
Calibration using background gas |
Not required |
|
Required |