| http://thietbitudong.ansvietnam.com/ |
|
| 04416A1 |
SERVOPRO NanoChrome Ar Background |
| |
includes report software, packaging |
| Impurities options |
|
| N2 Range 0-250ppb LDL 0.3ppb |
INJ with 1 valve |
| H2 Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2 valves |
| CO Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CO2 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CO2/CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb |
BF/HC/SEL with 3 valves |
| |
|
| Chassis options (Refer to SAP) |
|
| Master Chassis |
Max. 2 channels with 4 valves |
| PC+ Slave chassis |
2 BF/HC channels |
| Master +Slave1 Chassis |
Max. 4 channels with 8 valves |
| |
|
| Carrier Gas |
Helium |
| |
Argon only for N2 measurement |
| |
|
| Power |
115 VAC, 50-60 Hz |
| |
220 VAC, 50-60 Hz |
| |
|
| Gas Connectors (to match accessories fittings) |
1/8" VCR |
| |
|
| Serial port |
RS-232 |
| |
|
| |
|
| Remote Support |
VNC |
| |
Net Support |
| |
|
| Internal Dilution System |
Not Required( > 1ppm) |
| |
Required ( One per Chassis) |
| |
|
| |
|
| |
|
| 04416A1 |
SERVOPRO NanoChrome N2 Background |
| |
includes report software, packaging |
| Impurities options |
|
| Ar Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2 valves |
| H2 Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2 valves |
| CO Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CO2 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CO2/CH4 Range 0-250ppb LDL 0.5ppb |
BF/HC with 2 valves |
| CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb |
BF/HC/SEL with 3 valves |
| |
|
| Chassis options |
|
| Master Chassis |
Max. 2 channels with 4 valves |
| PC+ Slave chassis |
2 BF/HC channels |
| Master +Slave1 Chassis |
Max. 4 channels with 8 valves |
| Master +Slave 1 +Slave 2 Chassis |
Max. 6 channels with 12 valves |
| |
|
| Carrier Gas |
Helium |
| |
|
| |
|
| Power |
115 VAC, 50-60 Hz |
| |
220 VAC, 50-60 Hz |
| |
|
| Gas Connectors (to match accessories fittings) |
1/8" VCR |
| |
|
| Serial port |
RS-232 |
| |
|
| |
|
| Remote Support |
VNC |
| |
Net Support |
| |
|
| Internal Dilution System |
Not Required( > 1ppm) |
| |
Required ( One per Chassis) |
| |
|
| |
|
| |
|
| |
|
| SERVOPRO Plasma Gas Analyser (K2001) |
|
| |
|
| 02001A1 |
Trace Gas Analyser |
| |
|
| |
includes 4-20ma, digital dry contacts (range ID), manual/CDROM, packaging) |
| |
|
| Power |
115 VAC, 50-60 Hz |
| |
220 VAC, 50-60 Hz |
| |
|
| |
|
| Background |
Argon |
| |
Helium |
| |
Argon and Helium |
| |
|
| |
|
| Auto calibration |
Not required |
| |
Required |
| |
|
| |
|
| 3 Range ID |
0-1, 0-10, 0-100 (ppm) |
| |
0-10, 0-50, 0-100 (ppm) |
| |
|
| |
|
| Serial port |
Not Required |
| |
RS-232 |
| |
|
| |
|
| |
|
| |
|
| |
|
| SERVOPRO Chroma Gas Analyser (K4000) |
|
| |
|
| |
|
| 04401A1 |
Crude Ar Analyser (N2 in mix 10%Ar + 90%O2) Base |
| |
includes report software, 2 SS coils tubing, packaging |
| |
|
| Trace (>10 ppm), Pack 1 |
N2 Impurity - Enter range & LDL |
| |
0-10ppm ≤N2 range ≤ 0-500ppm LDL is 1.5% full scale |
| Carrier Gas |
Argon |
| |
|
| Power |
115 VAC, 50-60 Hz |
| |
220 VAC, 50-60 Hz |
| |
|
| Gas Connectors |
1/8" Swagelok |
| (to match accessories fittings) |
|
| |
|
| Serial port |
Not Required |
| |
RS-232 |
| |
|
| Remote Support |
VNC |
| |
Net Support |
| |
|
| Dual Inlets (sample + span, with switching) |
Not Required |
| |
Required |
| |
|
| Calibration using background gas |
Not required |
| |
Required |